

MBD model quality inspection and management
- MBDVidia software - CAD model format conversion + 3D model PMI annotation checking and management + importing measurement results into 3D models + automatically generating FAI and other reports
- MBD model quality management function plugin of CAD system - real MBD model + CAD model format conversion + automatic generation of 2D drawing bubble diagram + PMI human-readable + measurement result import into MBD model + automatic generation of FAI report
- CompareVidia Software - CAD Model Data Conversion and Verification Software ++ Automatically generates customizable reports + Complies with Boeing D6-51991 standards + CAD model file version management + 3D PMI annotation management
- Pundit Software - Intelligent CMM Detection Simulation Software + Optimized Measurement Plan + Measurement Plan Uncertainty Analysis + Simulated Detection Process + Finding Defects in GD&T
CAD Modeling and Repair
CAE Simulation Analysis
Environmental Stress Excitation Testing
- HAMT High Acceleration Maturity Test System - Improve Product Quality, Enhance Operational Efficiency, Accelerate Product Market Launch
- American HANSE Special Environment Test Chamber - Highly Accelerated Life Testing and Product Reliability Testing
- Electromagnetic Vibration Test System - Conducting product failure analysis through sinusoidal vibration, random vibration, and classical impact tests.
- Impact Testing Machine - Correction of Support Structure and Analysis of Material Properties
- Drop Test Machine - Product Structure Verification and Reliability Analysis
Vibration and Displacement Strain Measurement
- EikoTwin FE-DIC 3D Full-Field Non-Contact Optical Strain Measurement System
- HoloBright Laser Doppler Multi-Point Vibration Meter - Long-Distance Laser Vibration Measurement Equipment
- PMLAB DIC-3D Pro Traditional DIC Strain Measurement System - Full-field Non-contact Strain Measurement
- SP-SWI/SP-DWI Optical Static/Dynamic Surface Profilometer - Dynamic/Static Morphology Measurement + Resonant Frequency Detection
Sound and Vibration Measurement
- Signal-Wise Comprehensive Noise Diagnosis and Analysis System - Noise Source Localization + 3D Sound Field Reconstruction
- Signal-Wise X-tractor Intelligent Signal Recognition Quality Inspection Analysis System - Product QC Testing + Designated Defect Recognition
- SoundPLAN Noise Prediction Assessment Tool - Outdoor Noise Detection and Assessment Software
- SonoCat multifunctional acoustic measurement device - on-site sound source location, detection of sound pressure & sound intensity & material surface sound absorption effect parameters.
- Norsonic Far-field Sound and Vibration Measurement System - Noise Analysis + Noise Source Identification and Localization
- Synave Near-field 3D Acoustic Holography Measurement System - 3D Sound Field Reconstruction + Noise Source Localization
- Visual Signal Sound Signal Analysis Tool - Vibration Noise Signal Visualization
- COCO80/90 Dynamic Signal Analyzer - Handheld Noise Signal Recording and Analysis Device
Biomechanical Analysis
- BOB Human Muscle and Skeletal Simulation Modeling Software - Biomechanical Analysis of Movement
- BTS Biomechanical Motion Analysis System - Human Motion Data Collection Equipment
- PRO-GRF Ground Reaction Force Professional Analysis System
- SPI-Tactilus Foot Pressure Testing System - Real-time Contact Surface Pressure Analysis
- Vehicle Seat Comfort Measurement System - CASIMIR and MEMOSIK
SPI Surface Pressure Full-Field Measurement System
- SPI-FreeForm® Real-time Contact Pressure Testing System - Automotive Door Sealing Test - 1
- SPI-FreeForm® Real-time Contact Pressure Testing System - Automotive Door Sealing Test - 2
- SPI-Tactilus® Surface Contact Pressure Analysis System
- SPI-Tactilus® Flex Bending Degree Measurement Sensor
- SPI-Tactilus® Real-time Contact Pressure Measurement System (Heat Exchange Applications)
- SPI-Tactilus® Real-time Contact Pressure Measurement System - Pressure Indicating Washer
- SPI-Tactilus® Real-time Contact Pressure Testing System - Application in Heat Dissipation Equipment
- SPI-Pressures-micro®Green contact pressure indicating pressure-sensitive paper / pressure-sensitive film
- SPI-Tactilus Free From® Real-time Contact Pressure Testing System - Appliance Door Sealing Test
Non-destructive testing
SonoCat multifunctional acoustic measurement device - on-site sound source location, detection of sound pressure & sound intensity & material surface sound absorption effect parameters.
Make complex on-site noise measurement work easier!
In our living environment, there are many sources of noise, and some noises can interfere with our lives and even affect our health. Therefore, we need to identify the noise sources that impact our lives. However, the impact of noise is related to the listener's state and the way noise propagates, so we need measurement work to identify the problematic noise sources. Since measurement work is usually conducted in experiments, and laboratory measurement conditions may be limited by the environment, leading to discrepancies between measurement conditions and results compared to reality, we need on-site measurement equipment to obtain actual results.
SonoCat is a multifunctional spherical microphone array (see the figure below) composed of a set of 8 MEMs microphones for measurement. It can obtain the sound level (sound pressure level), 3D sound intensity vector, and surface material sound absorption coefficient from the measurement results. SonoCat can operate in two modes: single-point measurement and scanning measurement. In single-point measurement mode, we can measure the three-dimensional sound intensity vector at that location to find the sound source position; through scanning mode, we can obtain the average absorption coefficient of the measured surface material. SonoCat connects to a computer or tablet via USB cable, and through the SonoCat software, we can directly monitor, record, and analyze noise issues on-site.
Sound Absorption Coefficient Measurement Principle
The sound absorption coefficient of a material is defined by the ratio of the sound's active power to the incident power. However, the testing conditions on-site and in the laboratory may not be the same, and laboratory measurement results may deviate from on-site conditions. SonoCat is based on the Local Plane-Wave Method principle. We assume that the sound intensity components at the measurement point perpendicular to the measurement surface are plane waves of incident and reflected sound. As long as we measure positions close to the wall surface, we can assume that the plane wave is near the wall surface, allowing us to derive the on-site sound absorption coefficient of the wall material. Therefore, sound absorption coefficient measurement work is no longer limited to the laboratory; we can measure directly on-site!
Product Features
- Sound Level Measurement – Can measure A, C, and Z-weighted sound levels, calculated according to IEC 61672-1 standards.
- Material Sound Absorption Coefficient Measurement
- Sound Source Location – If the Active Power measurement result is negative, it indicates that the sound energy from the material surface is stronger than the incident energy, indicating a sound source (e.g., vibration noise source, leakage location).
Product Applications:
- On-site Material Sound Absorption Coefficient Measurement
- Sound Source Location
On-site Sound Absorption Coefficient Measurement Example
Automotive Industry Applications
Product Specifications
SonoCat Dimensions:365×65×45 mm
Weight: 210g
Sound Frequency Measurement Range: 20Hz – 20kHz
Sound Absorption Coefficient Measurement Range: 50Hz – 6300Hz
Sound Level Measurement Dynamic Range: 29 – 116dB(A)
Sound Measurement Sampling Frequency: 48kHz
Bit Depth: 24Bit
Product Packaging and Outer Box