MBD model quality inspection and management
- MBDVidia software — 3D MBD model creation and export + 3D model PMI annotation review and repair + import of measurement results into 3D models + automatic generation of FAI and other reports + automatic generation of balloon callouts on 2D drawings + 3D model lightweighting
- MBD Model Quality Management Plugin for CAD Systems — True MBD Models + 3D CAD Model Format Conversion + Automatic Generation of 2D Drawing Balloon Annotations + PMI Annotation Inspection + Import of Measurement Results into MBD Models + Automatic Generation of FAI Reports
- CompareVidia software — CAD model data conversion verification software + automatic generation of customizable verification reports + compliant with Boeing standard D6-51991 + CAD model file version management + 3D PMI annotation management
- Pundit Software — Intelligent CMM inspection simulation software + optimized measurement planning + measurement plan uncertainty analysis + simulated inspection process + identification of GD&T defects
- BALLOON2D software — specialized software for 2D drawing data extraction, PMI information recognition and editing, and 2D drawing digitization; automatic generation of FAI and other inspection reports; automatic creation of balloon diagrams for 2D drawings; 2D version of MBDViDia software.
CAD Modeling and Repair
CAE Simulation Analysis
- FlowVision Fluid Dynamics Analysis and Computation – CFD fluid simulation modeling software + large-amplitude motion simulation of objects + CFD simulation of flow channel opening and closing + geometric contact simulation and prediction + micro-gap flow simulation + strong fluid-structure interaction simulation and analysis
- AnyBody Biomechanical Analysis Software
Environmental Stress Excitation Testing
- HAMT High-Accelerated Stress Life Testing System – Improve Product Quality, Enhance Operational Efficiency, and Accelerate Time-to-Market
- U.S.-made HANSE Special Environment Test Chamber – Highly Accelerated Life Testing and Product Reliability Testing + Thermal Shock and Vibration Test Chamber + HALT/HASS Test Chamber
- Electromagnetic Vibration Test System – Conducts product failure analysis using sinusoidal vibration, random vibration, and classic impact testing.
- Impact Testing Machine – Modified Support Structure and Analysis of Material Properties
- Drop Test Machine – Product Structural Validation and Reliability Analysis
Vibration and Displacement Strain Measurement
- EikoTwin FE-DIC Three-Dimensional Full-Field Non-Contact Optical Strain Measurement System
- HoloBright Laser Doppler Multipoint Vibrometer – Long-Range Laser Vibrometry Equipment
- PMLAB DIC-3D Pro Traditional DIC Strain Measurement System – Full-Field, Non-Contact Strain Measurement
- SP-SWI/SP-DWI Optical Static/Dynamic Surface Profilometer – Dynamic/Static Topography Measurement + Resonant Frequency Detection
Sound and Vibration Measurement
- Signal-Wise Integrated Noise Diagnosis and Analysis System – Noise Source Localization + 3D Sound Field Reconstruction
- Signal-Wise X-tractor Intelligent Signal Recognition Quality Inspection and Analysis System – Product QC Testing + Specified Defect Identification
- SoundPLAN Noise Prediction and Assessment Tool – Outdoor Noise Monitoring and Evaluation Software – China Distributor – Beijing Qiaoze Technology
- SonoCat Multifunctional Acoustic Measurement Device — On-site source localization and measurement of sound pressure, sound intensity, and material surface sound absorption parameters
- Norsonic Far-Field Sound and Vibration Measurement System – Noise Analysis + Noise Source Identification and Localization
- Synave Near-Field 3D Acoustic Holography Measurement System – 3D Sound Field Reconstruction + Noise Source Localization
- Visual Signal Audio Signal Analysis Tool – Visualization of Vibration and Noise Signals
- COCO80/90 Dynamic Signal Analyzer – Handheld Device for Recording and Analyzing Noise Signals
- Synave-SynQC Industrial Product Quality Real-Time Automated Analysis System – Acoustic Quality Analysis + Real-Time Industrial Quality Control + Noise and Vibration Detection + Acoustic Analysis + Product Defect Detection
Biomechanical Analysis
- BoB/Markerless Markerless Human Motion Biomechanics Solution
- BOB Human Musculoskeletal Simulation Modeling Software – Biomechanical Analysis of Movement
- BTS SMART-DX EVO Human Motion Biomechanics Data Acquisition System – Distributed Intelligent Motion Capture System + Infrared Digital Cameras + Multi‑Space Calibration + Wireless Connectivity + Multi‑Scene Solutions + Authoritative Validation
- PRO-GRF Professional Ground Reaction Force Analysis System
- CASIMIR Seat Comfort Simulation Software — Seat Surface Pressure Distribution + Material Strain Analysis + Dynamic Comfort Analysis + Influence of Inter-Component Interactions on Comfort + Structural Design Optimization
- BTS SMART-DX EVO Human Motion Biomechanics Data Acquisition System – Distributed Intelligent Motion Capture System + Infrared Digital Cameras + Multi‑Space Calibration + Wireless Connectivity + Multi‑Scene Solutions + Authoritative Validation
SPI Surface Pressure Full-Field Measurement System
- SPI-Tactilus Foot Pressure Testing System – Real-Time Contact Surface Pressure Analysis
- SPI-FreeForm® Real-Time Contact Pressure Testing System – Automotive Door Sealing Test – 1
- SPI-FreeForm® Real-Time Contact Pressure Testing System – Automotive Door Sealing Test – 2
- SPI-Tactilus® Human Body Surface Contact Pressure Analysis System
- SPI-Tactilus®Flex Flexion Measurement Sensor
- SPI-Tactilus® Real-Time Contact Pressure Measurement System (Heat Exchanger Applications)
- SPI-Tactilus® Real-Time Contact Pressure Measurement System – Pressure Indicator Washer
- SPI-Tactilus® Real-Time Contact Pressure Testing System – Thermal Management Device Applications
- SPI-Pressures-micro®Green Contact Pressure Indicator Pressure-Sensitive Paper/Pressure-Sensitive Film
- SPI-Tactilus Free From® Real-Time Contact Pressure Testing System – Appliance Door Sealing Test
Non-destructive testing
BoB/Markerless Markerless Human Motion Biomechanics Solution
BOB / MARKERLESS · MOTION CAPTURE
BOB Markerless Motion Capture
An ordinary video, subjected to three-dimensional biomechanical analysis.
BoB/Markerless is an add-on module for the BoB biomechanics software: it requires neither reflective markers nor inertial measurement units (IMUs), and can estimate three-dimensional human motion from a standard video clip, which is then fed into BoB for biomechanical analysis. This significantly enhances the convenience of motion capture while substantially reducing hardware costs.
SPLYZA Motion captures ballet movements with a single camera, while the BoB musculoskeletal model simultaneously reconstructs them and overlays joint motion trajectories.
A real serve is shown side by side with the BoB skeletal model, making the motion details and technical features immediately apparent.
Top: BoB’s skeletal model reconstructs the throwing motion in a virtual arena; Bottom: Real-match footage—outdoor setting, markerless capture achievable with a single camera.
Top: A typical hosting video; Bottom: Real-time skeletal model tracking and reconstruction for BoB—no wearable devices required throughout the entire process.
CORE CONCEPT · 01
Why Choose Markerless Motion Capture
When optical tracking or IMU sensors are ill-suited to real-world conditions, measurements are cumbersome, and costs are high, BoB/Markerless enables motion capture using a smartphone or webcam—simply record a video with your phone or webcam to perform markerless motion capture.
TRADITIONAL
The practical barriers of traditional motion capture methods
● Optical tracking requires attaching marker points to the human body, making the setup cumbersome.
● IMU solutions require wearing inertial sensors.
● The equipment and scene setup are expensive.
● In many measurement scenarios, it does not match the actual operating conditions.
BOB / MARKERLESS
A single ordinary video is all it takes to get started.
● Do not place marker points , also No IMU required , no wearing burden
● Simply record a video with your phone or webcam.
● Existing video files can also be imported, to do Retrospective analysis
● Significantly enhance convenience and substantially reduce hardware costs.
HOW IT WORKS · 02
BoB/Markerless Working Principle
BoB's markerless workflow is the same as other BoB products; the only difference is that it can use video files to import the subject's movements — a single camera + SPLYZA Motion handle the "seeing", and BoB is responsible for the subsequent biomechanical calculations.
STEP 1 Video Capture
A single camera is all you need: record a motion video using your smartphone or a webcam; alternatively, you can directly use an existing video file for retrospective analysis.
● A single camera is sufficient; no additional equipment is required.
● Supports importing existing video files
STEP 2 AI Pose Estimation
SPLYZA Motion uses AI to estimate 3D joint positions from monocular 2D video, requiring only a single camera and no additional equipment.
● 40+ key points (including thoracic spine, lumbar spine, pelvis, and center of gravity), available offline and in batch mode
STEP 3 Import BoB
The BoB/Markerless plugin imports motion data into BoB: SPLYZA Motion’s data—BVH files exported from video.
● The operating procedure is consistent with other BoB products.
STEP 4 BoB Musculoskeletal Model Computation
Musculoskeletal model analysis is computed as usual for BoB products: the workflow and use of marker points/IMU motion capture data are the same; only the source of motion has been replaced with video.
● Once 3D skeletal motion is available, BoB computes as usual.
STEP 5 Biomechanical Results Output
Outputs BoB’s general biomechanical results and can overlay ergonomics analysis capabilities (see the parameter list below for details).
● Joint angles / ROM / Torque / Muscle forces / Ground reaction forces, etc.
Figure: BoB/Markerless – Markerless Biomechanical Analysis Workflow (based on product documentation “BOB Markerless Motion Capture”)
BoB Computable Biomechanical Parameters
· Point position / velocity / acceleration
· Segmental posture, anatomical trajectory
· Center of mass position, body energy / power
· Joint angle, range of motion (ROM), joint torque
· Muscle force, muscle length, muscle contraction rate
· Muscle Energy / Power
· Joint contact forces, ground reaction forces, velocity vectors
· Input and output before and after filtering
It can still be calculated after superimposing BoB/Ergo.
+ REBA / RULA Scoring
+ NIOSH Revised Lifting Equation
+ISO11228
+ Spinal Compression and Shear Forces
+ Resultant Force / Resultant Moment
+ Comparison / Sequential / Sensitivity Analysis
+ First-person perspective, etc.
It is also compatible with all data interface formats in the BoB series.
C3D CSV Perception Neuron's Calc Xsens MVNX BVH (Biovision / MotionBuilder / SPLYZA / Captury / Blender), etc.
REQUIREMENTS · 03
BoB/Markerless Usage Conditions
The entry barrier is very low: a camera, a BoB device, and an SPLYZA Motion subscription—plus a Windows PC—are all you need to get started.
Condition 1
Mobile phone or webcam
A smartphone or a webcam is all you need to record video.
Condition 2
A BoB product
Core, EMG, or Ergo are all acceptable (except BoB/Teaching).
Condition 3
SPLYZA Motion Subscription
Additionally, subscribe to SPLYZA Motion (sold separately; a free trial is available).
Condition 4
Windows PC
BoB software runs on the Windows platform.
APPLICATIONS · 04
Applicable Scenarios
From the workshop to the competition arena, from the clinic to historical footage—any motion that can be captured in a video sequence is suitable for BOB/Markerless, a markerless human motion biomechanics solution.
Ergonomic Analysis · Industrial Design
Ergonomic analysis of the workplace; after integrating ergonomic capabilities, it can output REBA/RULA scores, NIOSH lifting equations, and more.
Sports training
Analyze the movements of a single athlete, or compare the differences in how different athletes perform the same movement.
Physical therapy
Track changes in movement during the rehabilitation process to provide quantitative reference for rehabilitation assessment.
Retrospective Video Analysis
Conduct a retrospective analysis of existing video footage—historical recordings can also be converted into biomechanical data.
WHY QIAOZE · 05
Why Choose Joeze
◆
BoB has a complete product line.
Core / EMG / Ergo / Teaching/Markerless Multi‑Version Licensing: Available in various forms, including long‑term perpetual licenses and annual multi‑seat educational licenses, offering convenience and flexibility.
◈
Free Trial Access
BOB software products are available for free trial; the SPLYZA Motion subscription required for BoB/Markerless is also available for trial.
⚙
Local Support Team
The Chinese local team provides consulting and support (one hour of user support is included with each BoB license), helping you get up and running across the entire workflow, from capture to reporting.
●
Complete Biomechanics Protocol Suite
Combined with products such as BTS SMART-DX infrared optical motion capture, BTS-FreeEMG wireless electromyography, and Pro-GRF, it covers all scenarios—both with and without markers.
Get a BoB/Markerless trial and solution consultation
Feel free to inquire about BoB product versions and licensing options, request trial access to BoB/Markerless and SPLYZA Motion, or explore integrated solutions with EMG, force‑sensing, or pressure‑distribution devices. We can provide tailored recommendations based on your specific use case.
Manager Su
Biomechanics Products Division · Beijing Qiaozе Technology Co., Ltd.
Working hours: Monday to Friday, 9:00 AM – 6:00 PM | Official website: www.deanwell.com.cn