When choosing noise prediction software, don’t rely solely on price quotes: SoundPLAN uses ISO 9613-2 and ray tracing to calculate the insertion loss of noise barrier designs.
Release time:
2026-10-10 17:07
Source:
When it comes to noise control, cutting corners on calculations is the last thing you should do. Noise prediction software If you choose a solution based solely on the interface and price, the decision can easily get stuck at the quotation stage. In this article, we break down three key points using ten of the latest studies from 2025–2026: Noise Simulation and Prediction How to evaluate software, SoundPLAN What are the strengths of its compute core? Sound barrier How does the scheme calculate all the way to the insertion loss level?
01 Key Considerations for Selecting and Evaluating Noise Prediction Software
HOW TO JUDGE A NOISE SOFTWARE
Before deciding whether to buy a noise prediction software, don’t focus on the interface or price; instead, consider three key factors: the standards underlying its computational engine, the sources of its input data, and whether its outputs can be directly translated into actionable mitigation measures. Three studies conducted between 2025 and 2026 happen to quantify all three of these aspects.
First thing: the quality of input data determines the ceiling for predictions.
At three representative test sites in Italy and Romania, researchers fed microwave radar counters, AI cameras, and Google API traffic flow data separately into the CNOSSOS-EU model, then compared the results with on-site measurements: errors in traffic volume and vehicle type distribution from different data sources were amplified by the propagation model; the Google API traffic flow performed well only when traffic exceeded approximately 150 vehicles per hour and the model had been carefully calibrated [1].
“The traffic volumes and vehicle-type distributions from the three data-collection methods were each fed into a noise simulation and then compared with field measurements—any discrepancies in data quality are directly reflected in the prediction error.”
Second: predictions must be empirically testable and calibrated.
Research on sensitive buildings in urban rail transit has established a standard procedure: first conduct multidimensional on-site noise monitoring, then apply a hybrid prediction method combining “code-based formulas, numerical simulation, and experimental studies.” This approach keeps overall prediction–measurement errors within 3 dB(A) and front‑facade prediction errors within 2 dB(A), fully meeting environmental noise assessment requirements [2].
Third: The software must be able to directly answer whether the levels exceed regulatory limits.
Modeling a four-leg signalized intersection in Makassar, Indonesia, using SoundPLAN 9.0: peak noise levels on weekdays reached 76.49 dB, while the local permissible standard is 70 dB; the software output directly points to mitigation options—optimizing signal timing or installing sound barriers [3].

Figure 1: Standard operating procedure for measuring and calibrating LAeq at intersections (adapted from reference [3])
02 Analysis of SoundPLAN Software Functions
INSIDE SOUNDPLAN
The computational core represents the first major dividing line. SoundPLAN supports mainstream international prediction models such as ISO 9613-2, CNOSSOS-EU, and NMPB-96, employing ray tracing to account for obstruction, reflection, and ground absorption—allowing the same modeling framework to seamlessly switch between standards rather than requiring a complete rebuild from scratch.
Trunk Line Case: How Accurate Are the NMPB-96 Internal Calculations? Let the Measured Data Speak for Itself
Istanbul’s D-100 and TEM trunk roads were modeled using SoundPLAN (NMPB-96 method), with absolute prediction–measurement errors of only 1.3–1.7 dB(A). Following implementation of mitigation measures, noise levels decreased by approximately 4 dB(A), reducing the number of residences exposed to sound levels above 75 dB(A) from 10,898 to 4,451—a reduction of 59% [4].

Figure 2: Three-dimensional noise simulation results for the D-100/TEM trunk line (NMPB-96 kernel) (reproduced from reference [4])
Airports and Special Sound Sources: From Traffic Flows to Helicopters Can All Be Incorporated into the Model
The standard practice for airport noise assessments involves generating noise maps using commercial software and then overlaying CORINE land cover data to identify sensitive areas. At Sabiha Gökçen Airport, the IMPACT tool was used to produce contour maps, revealing that a hospital experiences 65 dB during approach phases, an industrial zone reaches up to 70 dB during takeoff, and schools and residential areas fall within the 65 dB contour. The review also notes that four international airports in Turkey have employed SoundPLAN to conduct similar mapping and overlay analyses [5].

Figure 3: Noise contour map of Sabiha Gökçen Airport and identification of sensitive areas (adapted from reference [5])
Special sound sources can also be incorporated into the model: The NORAH2 helicopter noise model uses a hemispherical source approach and, in Cannes, replayed 556 flight operations from May 12–25, 2025, using ADS-B data to generate end-to-end urban helicopter noise maps [6]. Kernel compatibility determines whether the software can sustain long-term business needs.
03 Noise Prediction Solutions
FROM PREDICTION TO MITIGATION
Sound barriers: First calculate the insertion loss, then decide how much to spend.
Sound barriers are the mainstay of traffic noise control, but their effectiveness diminishes when moving from design plans to actual field conditions. A case study evaluating sound barrier performance used the ISO 10847 field measurement method to quantify how ground reflection and meteorological conditions affect actual insertion loss [7]—the value of predictive software lies precisely in accounting for these losses in advance when designing mitigation solutions.

Figure 4: Principle of calculating the geometric path difference for the insertion loss of a sound barrier (adapted from reference [7])
Advances are also being made on the materials front: sound barriers made from recycled plastics and rubber granules achieve a sound insulation rating of RW = 39.7 ± 1.0 dB at 1250 Hz [8]; simulated peak transmission loss TLa for acoustic crystal barriers reaches 45.8 dB (2×4 array), while measured experimental values are only 10.1 dB (2×6 array)—the discrepancy between simulation and measurement itself underscores the necessity of “simulate first, then fabricate” [9].
Substation-Level Integrated Solution: Coupled Model + Coordinated Optimization
A detailed study of a 500 kV substation shows that, based on SoundPLAN noise predictions, a well-planned building layout combined with sound barriers can reduce main transformer noise by 6–15 dB(A), installing silencers can achieve approximately 10 dB(A) reduction, and upgrading the enclosure structure can yield up to 30 dB(A) [10].

Figure 5: Predicted noise contour lines for the sound barrier scheme at a 500 kV substation (adapted from reference [10])
The study further employs a noise coupling analysis model to capture the superposition effects of multiple devices and uses a genetic algorithm for the coordinated optimization of multiple measures: overall noise reduction of 38.5–40.2 dB, which is 8–12 dB higher than that achieved with single-scale optimization; the coefficient of variation is 0.04, significantly lower than the 0.09 obtained by the PSO algorithm and the 0.16 of conventional methods [10].
From trunk lines, intersections and airports to substations, projects are becoming increasingly complex, yet noise‑prediction software still serves the same purpose: letting every mitigation investment demonstrate decibel‑level returns before construction begins. SoundPLAN places sources, propagation and receivers into a single model, batch‑generates noise maps according to ISO 9613‑2, CNOSSOS‑EU and NMPB‑96, and directly provides insertion‑loss comparisons for barrier designs — choosing the software is, in essence, choosing the certainty of the mitigation plan.
Insertion loss cannot be calculated on the quotation; it can only be determined in the model.
References
[1] Influence of Traffic Input Data Quality on Road Noise Estimates Using CNOSSOS-EU. Sensors, 2026. DOI:10.3390/s26030778
[2] On-Site Monitoring and a Hybrid Prediction Method for Noise Impact on Sensitive Buildings. Buildings, 2025. DOI:10.3390/buildings15173227
[3] Prediction of Traffic Noise Levels at Signalized Four-Way Intersections in Makassar. Engineering Technology & Applied Science Research, 2025. DOI:10.48084/etasr.14327
[4] Modeling and Mitigation of Road Traffic Noise in a Major Hub for Urban Transportation. Sustainability, 2026. DOI:10.3390/su18126143
[5] Noise Mapping for Sabiha Gokcen Airport Using IMPACT Tool. Eskişehir Technical University Journal of Science and Technology A, 2025. DOI:10.18038/estubtda.1715489
[6] Helicopter Noise Modelling in an Urban Setting: A NORAH2 Demonstration in Cannes. Aerospace, 2025. DOI:10.3390/aerospace13010037
[7] Case Study on the Assessment of Sound Barrier Performance for Traffic Noise Reduction. Journal of Vibroengineering, 2026. DOI:10.21595/jve.2025.25413
[8] Development of Noise Barrier Made from Recycled Plastic and Rubber Granules. Buildings, 2026. DOI:10.3390/buildings16071294
[9] Development of Sonic Crystal Noise Barriers with Simulations and Experiments. American Journal of Physics and Applications, 2026. DOI:10.11648/j.ajpa.20261404.11
[10] Research on Noise Prediction and Management Measures of 500kV Substation Based on SoundPLAN. PLoS ONE, 2026. DOI:10.1371/journal.pone.0344581
Noise prediction software,Noise Simulation and Prediction,Noise Control,Sound barrier,SoundPLAN,ISO 9613-2 and ray tracing
Previous Page