High-Performance Fluid–Structure Interaction Simulation Solution: FlowVision’s native two-way coupling capability with Abaqus, combined with its ability to handle complex motions and deformations, enables it to excel in the biomedical and aerospace fields.
Release time:
2026-09-11 16:50
Source:
At a time when digital design and precision medicine are deeply integrated, strong fluid–structure interaction (FSI) simulation is evolving from a mere “supporting tool” to a core component of R&D decision-making. Leveraging its native two-way coupling architecture with Abaqus and its capability to handle large deformations, large displacements, and multi-body motion, the FlowVision fluid simulation software continues to deliver tangible engineering value in the highly demanding fields of biomedicine and aerospace.
What exactly is being calculated in strong fluid–structure interaction simulation analysis?
The structure deforms under fluid loading, and the deformed geometry in turn reshapes the flow field—when this “two-way feedback” cannot be neglected, a strong (two-way) coupling solution must be employed: at each time step, the fluid solver and the structural solver iteratively exchange pressure loads and displacement data until both the interface forces and displacements converge.
The opening and closing of heart valves, structural impacts during a helicopter’s emergency water landing, and large deformations in packaging material forming are all typical strongly coupled problems: one-way weak coupling can miss critical instantaneous feedback, leading to distorted predictions of peak loads and motion patterns. [1][2] 。
02
PART 02
Native two-way coupling with Abaqus: direct connection instead of assembly
The coupling between FlowVision and Abaqus employs Native Direct Connection Method — The two solvers communicate directly, without relying on any third-party middleware, and payload transfer and interpolation errors are fully controllable. [3] 。
Its methodological foundations can be traced back to the seminal work presented at the 2004 Abaqus User Conference: leveraging FlowVision’s unique mesh-generation technology to enable coupling between structural and fluid domains. Fully Conserved (No Data Loss) Bidirectional Data Transfer and maintain the approximate accuracy of the governing equations throughout the coupling process without degradation. [1] . A study on numerical algorithms for strong coupling, published in 2017 in the Chebyshev Collection, further systematically verified the stability and convergence of this framework in problems involving strong interactions. [2] 。
03
PART 03
Handling Complex Motion and Deformation: Three Key Technological Pillars
FlowVision’s core competitive advantage as a strongly coupled solution is centered on three key technologies:
SGGR Subgrid Geometry Analysis : No body-fitted mesh is required; surface boundaries smaller than the mesh scale are resolved directly on a coarse hexahedral mesh. Combined with adaptive refinement, it naturally accommodates large-deformation interfaces. [1][4] ;
MB Moving Bodies Motion Technology Supports independent definition and interaction of multiple moving/deforming objects, covering complex operating conditions such as rotation, translation, and free motion.
GAP Gap Model : Analyzing leakage flow within micron-scale gaps is indispensable in scenarios such as valve leaflet coaptation margins and sealing structures.
From full-process FSI simulations of large deformations in Tetra Pak packaging to multiphase flow–structure coupling problems such as tire hydroplaning, the Direct Coupling interface enables engineers to perform complete “fluid + structure + coupling” modeling within a unified workflow. [5][6] 。
04
PART 04
Biomedicine and Aerospace: Two Flagship Application Domains
▍Biomedical Field The Imperial College London team is in Frontiers in Bioengineering and Biotechnology In the published fully coupled FSI model of a patient-specific biological aortic valve, FlowVision was used to solve the flow field; its results showed good agreement with 4D Flow MRI data and provided additional information—such as wall shear stress—that cannot be obtained from imaging alone. [4] In 2026, the IRCCS ISMETT and Medividia teams will further complete clinically validated patient-specific two-way FSI modeling for TAVI patients—using Abaqus/Explicit to simulate stent deployment, coupled bidirectionally with FlowVision, and employing probabilistic analysis in accordance with ASME V&V 40 principles to compare postoperative measured peak flow velocity, effective orifice area, and transvalvular pressure gradient. [7] . In a population-level validation study published concurrently in APL Bioengineering, this type of model demonstrated prediction errors for device diameter within 5% of the area measurement and errors in hemodynamic metrics within 10%. [8] Furthermore, a 2026 review published in the leading domestic journal Medical Biomechanics also notes that fluid–structure interaction (FSI) simulation has become a core tool for the development of cardiac valve devices, risk assessment, and preoperative planning. [9] 。
▍Aerospace Sector At the 33rd European Rotorcraft Forum, Kazan Helicopter Company and TESIS jointly presented an application of the FlowVision-Abaqus direct coupled method to helicopter ditching impact problems, demonstrating the capability of strong coupling methods to capture extreme transient fluid-structure interaction events. [3] Cardiovascular research, including hemodynamic CFD simulations, continues to provide quantitative evidence to support medical device design and patient diagnosis and treatment. [10] 。
From heart valves to helicopter autorotations, strong fluid-structure interaction is setting the standard for high-fidelity simulations.
References |References
Aksenov A, Dyadkin A, Luniewski T, et al. Fluid Structure Interaction Analysis Using Abaqus and FlowVision[C]//Abaqus Users' Conference, 2004: 1-9.
Aksyonov A. A., Zhlutkov S. V., Son E. E., et al. Solving Fluid–Structure Interaction Problems Using the FlowVision and CAE FIDESYS Software Suites[J]. Chebyshevsky Collection, 2017, 18(3): 28-43.
Aksenov A, Iliine K, Schelayev A, et al. Modeling Fluid Structure Interaction for Aerospace Applications[C]//33rd European Rotorcraft Forum (ERF), Kazan Helicopters / TESIS / Capvidia, 2007: 1-12.
Yin Z, Armour C, Pirola S, et al. A Fully Coupled Fluid-Structure Interaction Model for Patient-Specific Analysis of Bioprosthetic Aortic Valve Haemodynamics[J]. Frontiers in Bioengineering and Biotechnology, 2025, 13: 1584509.
Mameli A, Magnusson A, Aksenov A, et al. Simulating the Pouch Forming Process Using a Detailed Fluid-Structure Interaction[C]//2013 SIMULIA Customer Conference, 2013: 1-15.
Sung M F, Chen C F, Chen C J. Using the CFD Technique to Analyze Tire Tread Hydroplaning Effects[J]. Asian Journal of Engineering and Technology, 2015, 3(3): 151-157.
Catalano C, Ozturk D, Bastron M, et al. Clinically-Validated Fully-Coupled Patient-Specific Fluid-Structure Interaction Modeling of TAVI Hemodynamics[J/OL]. Research Square (Preprint), 2026.
Catalano C, Scuoppo R, Turgut T, et al. Credibility Assessment of Patient-Specific Modeling in Transcatheter Aortic Valve Implantation. I. A Population-Based Validation[J]. APL Bioengineering, 2025, 9(4): 046101.
Wang Shengzhang, Cai Yunhan, Ju Jiayi. Advances in computational modeling and simulation of heart valves [J]. Medical Biomechanics, 2026, 41(2): 331-338.
Vucinic D, Yang T, Aksenov A. Human Heart Blood Flow Simulations Based on CFD[J]. International Journal of Fluids and Heat Transfer, 2016, 1(2): 15-34.